2012.10.14 this information is very outdated.
Reactor loop
-
Steam separator x 2
-
Switch input to steam separator 1..2 on and of
-
Steam exit temperature gauges for steam separator 1 and 2
-
Steam exit speed for steam separator 1 and 2
-
Water level in steam separator 1 and 2
-
Main circulaton pump x 4
-
Adjust speed of main pumps
-
Switch main pump 1..4 on / off
-
Main pump 1..4 status lights
-
Main loop valves x 4
-
Main flow speed gauges 1..4
-
Piping to reactor x 37
-
Pressure tubes x 37
-
Piping to steam separator from reactor
Turbine loop
-
Steam separator x 2
-
Adjust steam output level to turbine
-
Steam separator to turbine piping
-
Switch steam to turbine 1..2 on / off
-
Turbine x 2
-
Speed gauge for turbine 1..2
-
Voi hajota
-
Bearings can overheat
-
Voi vuotaa
-
Tuotta sähköä
-
Model inertia
-
Generator can be disconnected from external network and/or internal
-
Condenser x 2
-
Switch steam input to condenser 1..2 on / off
-
Temperature gauge for condenser 1..2
-
Water tank x 2
-
Water tank level gauge for tank 1..2
-
Water pump x 2
-
Adjust water pump speed
-
Turn water pump 1..2 on / off
Cooling loop
-
Water inlet x 2
-
Voi tukkeutua esim kaloista
-
Cooling river water pump x 2
-
Adjust river water pump power
-
Turn river water pump 1..2 on / off
-
Voi tukkeutua
-
Voi hajota
-
Condenser x 2
-
(Switch river water input to condenser 1..2 on / off)
-
Voi vuotaa -> radioaktiivista vettä jokeen
-
Voi rikkoutua -> radioaktiivista höyryä laitokseen
-
Cooling water outlet x 1
Emergency cooling loop
-
Emergency water tank x 1
-
Emerency water pump x 1
-
Switch emergency cooling water pump on/off
-
Emergency water valves x 2
-
Open / close emergency water valves
Electricity wiring
-
Generator x 2
-
External power output
-
Connect external power output on / off
-
External power input
-
Switch external power grid input to plant power on/off
-
Diesel generators
-
Startup 10 seconds
-
Manual startup (and stop?) emergency generators
-
Pumps etc use elctricity
-
Internal power level warning indicator (or gauge?)
-
Emergency power indicator light
-
No power indicator light
Control Panels
Plant Panel
-
Bottom
-
Used switches: 10 adjustable, 14 on/off (11 red, 4 black), 3 turnwitches
-
Reactor Loop - 4 on/off, 2 adjustable
-
2 Steam separators
-
Steam separator 1..2 input on / off (red)
-
4 Main pumps (adjustable)
-
Each pump supplies water to mostly one corner of the reactor
-
Main pump 1..4 on / off (red)
-
Increase / decrease main pump 1..4 power
-
Turbine Loop - 6 on / off, 4 adjustable
-
2 Turbines (adjustable)
-
Increase / decrease steam throughput to turbine 1..2
-
Turbine 1..2 (steam input) on / off (black)
-
Steam condenser
-
2 Water pumps (adjustable)
-
Increase / decrease water pump 1..2 speed
-
Turn water pump 1..2 on / off (red)
-
Cooling Loop - 2 on/ff, 2 adjustable
-
2 River water pumps (adjustable)
-
Increase / decrease river water pump 1..2
-
Turn river water pump 1..2 on / off (red)
-
Emergency - 3 red pushbuttons
-
Turn emergency cooling pump on / off (red)
-
Emergency venting of steam (into bubbler pool? Or atmosphere?) (red)
-
Turn emergency diesel generators on / off (pushbutton, red)
-
Electricity - 3 turnswitches
-
Connect generator 1..2 to external power on / off
-
(Use external grid power for plant on / off ?)
-
Mid
-
Main pump x 4
-
Steam separator x 2
-
Water temperature 0..400 Celsius
-
Steam pressure 0..10 MPa
-
Turbines x 2
-
Generated power 0..700 MW
-
River pump x 2
-
Cooling pump x 2
Gauges
-
Size: 10 x 10 cm
-
Readings:
-
8 x 0..125%
-
2 x 0..700 MW
-
2 x 0..400 C
-
2 x 0..10 MPascal
Component sizes
-
Turnswitch x3 with knob, 2 without
-
Single large pushbutton (11 red, 5 black))
-
Dual large pushbuttons (19 black (of wich 6 have one long edge shortened))
-
Mounting panel
Layouts